Case study · north London · basement flat, 1850 to 1918

Damp in every room.
A damp proof course comes last, if at all.

A buyer asked us to find the cause of the damp in the walls and floors of an empty basement flat. Every room had it. The answer was not one cause but several, and the order in which to deal with them is most of the value.

See exactly what you get: read a real Vigilant report, published with the client's permission.

Fixed fee from £350Surveyed after heavy rainDamp proofing not the first responseReal survey, not a mock up
This is a real Vigilant survey, published with the client's written permission. The client's name, the address and the postcode have been removed, and no photograph shows anything personal or identifies the property. Every reading, temperature, photograph and finding is exactly as recorded on site.

Buying a basement flat with damp patches in every room

The buyer wanted to know what was causing the damp recorded in the walls and floors of the flat, and what work it would need. The flat was empty, with keys from the agent, so there was no occupier to give a history. We did not know whether there had been leaks, flooding or heating repairs.

This is a damp and mould investigation. It is not a building survey or a valuation, and it does not replace either.

The flat

A purpose built flat at basement level, in a building of 1850 to 1918. Solid brick walls and a solid floor, both assumed and not established by opening up. No damp proof course was visible on any elevation. Heating by a gas combination boiler, its gauge reading 1.5 bar on the day.

Every room was surveyed: the living room, the bathroom, two bedrooms, the kitchen and the hallway, with the front, side and rear outside. The survey followed heavy rain over the previous 48 hours, with light rain at the time.

Is it rising damp? The highest readings were halfway up internal walls

Each room was measured against its own control, taken on a dry internal wall: living room 13.4, bathroom 11.2, bedroom 1 10.2, bedroom 2 13.6, kitchen 12.6 and hallway 13.5 %WME.

The highest readings are on internal walls with no outside face. This is the wall between the bathroom and the living room, seen from the bathroom side:

HeightLeftCentre leftCentre rightRight
200mm below ceiling10.91211.99.5
1200mm15.31001007.9
600mm16.310010063
Skirting, 100mm16.612.817.5not reached

Control in this room: 11.2 %WME.

100 at 600mm and 1200mm, with 7.9 to 16.3 beside it, and lower readings at the skirting below. Ground moisture does not do that. It is highest at the base and falls with height. Similar isolated readings of 100 were recorded on the living room chimney breast wall at 1200mm, the wall between the living room and the kitchen, the bedroom 2 wall to the hallway and the hallway wall. These patches have sharp edges, with dry readings a hand's width away, and efflorescence was seen in the bathroom, bedroom 2, the kitchen and the hallway.

That pattern is the signature of salts, and several of the patches are higher on the wall than ground moisture would normally reach. A meter reads salts and moisture alike, so these are elevated readings, not a measure of water.

Where did the salts come from? Look at the radiators

Corrosion was photographed at the living room radiator valve, with staining on the skirting and the floor finish around the pipe. Corrosion and staining were recorded at the bedroom 2 radiator. The floor finish read 22.4 and 20.3 on the meter's timber setting beside the living room skirting, a comparative reading only, and the floor finish has buckled in both bedrooms.

That points to water escaping from the heating at some point. Whether it is still happening is not known. With no clear sign that a leak is live, the report treats it as a past leak until a pressure test shows otherwise.

But the base of the walls is damp too

It is. Elevated readings of 20 to 32.5 were recorded at skirting level in bedroom 1, bedroom 2 and the kitchen, and up to 62.8 at the bathroom floor junction.

Outside, concrete and paving meet the walls on a level fall, with no damp proof course visible. Moss and staining run along the lower walls, and splashback was recorded on the side elevation. That is highly probable on the evidence to be keeping the base of the walls damp.

On the kitchen side wall, readings reach 100 at 600mm and 1200mm around the window, where the sealant above the window is exposed and the render is cracked and flaking. Rain getting in there is highly probable on the evidence.

And condensation on top

RoomColdest surface against dew point
Hallway, front door reveal2.9 degrees below
Kitchen, external wall under the window2.5 degrees below
Bedroom 2, rear external wall1.6 degrees below
Bedroom 1, rear external wall1.5 degrees below
Bathroom0.4 degrees above
Living room0.3 degrees above

Condensation was occurring on four of those surfaces on the day. No room has trickle vents, the door undercuts are 2mm to 5mm, the bathroom fan runs on a manual switch with its discharge unknown, and trace mould was seen in three rooms.

What was ruled out, and on what evidence

Supported Plumbing or drainage leak
Corrosion at the radiator valves, staining on the skirting and floor finish, readings of 22.4 and 20.3 along the floor, and buckled floors in the bedrooms. Treated as a past leak until a pressure test shows otherwise.
Supported Salt contamination of plaster
Efflorescence in four rooms. Readings of 100 stop sharply beside dry readings of about 8 to 16, which is the signature of salts. The salts may be linked to a past escape of water.
Supported Bridging or construction defect
Concrete and paving meet the front, side and rear walls on a level fall, no damp proof course was visible, moss and staining run along the lower walls, and splashback was recorded on the side elevation.
Supported Penetrating damp, building defect
The kitchen side wall reads up to 100 on both sides of the window, where the sealant above it is exposed and the render is cracked and flaking.
Supported Surface condensation
Cold surfaces below the dew point in four rooms, by 1.5 to 2.9 degrees, and within half a degree of it in the other two. No trickle vents and small door gaps.
Cannot exclude Rising damp
No damp proof course was visible and readings of 20 to 32.5 were recorded at skirting level in several rooms. But many of the highest readings sit at 600mm to 1200mm above dry readings at the skirting, which ground moisture would not explain. Drilled samples would settle it.
Cannot exclude Penetrating damp, wind driven rain
The survey followed heavy rain, and the external walls in bedroom 1 and the kitchen read above their controls. Cracked render and poor pointing were recorded.
Cannot exclude Historic or residual moisture
Salts, staining, blown plaster and buckled floors throughout carry the signs of a past escape of water. Whether such an event happened, and when, is not known.
Excluded Interstitial condensation
Solid walls, assumed from their method of construction, with no insulated lining recorded.

The evidence

Photographs from the survey, exactly as taken.

Living room, damp patch left of the radiator.
Living room, damp patch left of the radiator.
Blistered paint and salting at the 100 reading.
Blistered paint and salting at the 100 reading.
Living room, 22.4 along the floor finish beside the skirting, on the meter's timber setting. A comparative reading only.
Living room, 22.4 along the floor finish beside the skirting, on the meter's timber setting. A comparative reading only.
Bathroom, the damp patch on the wall.
Bathroom, the damp patch on the wall.
Bathroom, 62.8 recorded at the floor junction.
Bathroom, 62.8 recorded at the floor junction.
Bathroom, salts on the wall.
Bathroom, salts on the wall.
The right hand radiator tail.
The right hand radiator tail.
Buckled floor finish.
Buckled floor finish.

So what is causing it?

On the evidence, the damp in this flat most probably has several causes acting together.

The worst walls are internal, between the living room and the bathroom, and their readings have the signature of salts left by past water, most probably from the heating pipework, where corrosion and staining were seen at the radiators. External works will not reach these walls.

At the base of the walls, concrete and paving laid against the building, with no damp proof course visible, are highly probable on the evidence to be bridging the base of the wall and splashing moisture onto it. On the kitchen side wall, rain entering around the window and through the cracked render is highly probable on the evidence. Condensation is adding to the problem in every room.

Rising damp could not be excluded, but the outside defects and the past leak explain the readings first.

What to do about it, and in what order

First, have the heating pipework and radiator valves checked and pressure tested, and any leak repaired, then let the area dry. It is not known whether water is still escaping, so this comes before any drilled samples or replastering. We identify the likely source. We do not open up floors or walls to find it.

Form an air drain along the base of the side and rear walls where the concrete and paving meet them, so the hard surface stops splashing rain onto the wall and the base of the wall can dry. Make sure no gutter or downpipe discharges onto it.

Reseal the perimeter of the kitchen side window and repair the cracked render on the side elevation, with a breathable paint. Repoint the rear elevation in a mortar softer than the brick.

Clear the front light well gully, and unblock the side gully and confirm where the side downpipe discharges.

Improve ventilation: background ventilation to the rooms that have none, a clear gap under the internal doors, and the bathroom fan set to run on with a timer or humidity control and confirmed to discharge outside.

Clean the mould with detergent and water or a mould and mildew cleaner. Bleach is not needed. It is likely to return until the causes above are dealt with.

Once the heating is repaired and the walls have had a drying period, remove the salt contaminated plaster back to the masonry and replaster with a salt resistant system. On several walls that means above 1.5m. A breathable lime based renovating plaster suits a solid wall.

A damp proof course only if drilled samples, taken after the outside works and a drying period, still show ground moisture rising. Treating before the other causes are dealt with risks paying for work the wall does not need.

And what should not be done

Do not redecorate or replaster until the sources are dealt with and the walls have been measured again.

How confident, and what would settle it

The report records this as requires further investigation, not as highly probable, and it is explicit about why. Drilled samples from the high points on the internal walls and the base of the external walls, tested for moisture content and for salts against a control sample from a dry part of the same wall, would show how much is salt left by past water and how much is still arriving. A pressure test would show whether the radiator pipework is still losing water. Lifting the floor finish where it has buckled, with the owner's consent, would show the condition of the floor beneath. And the owner could be asked for any history of leaks, flooding or heating repairs.

For a buyer, that is the useful answer: what is known, what is not, and exactly how to find out before committing.

Buying a property with damp in the report?

Fixed fee from £350. We carry out no remedial work, sell no products, and take no commission or referral fee from anyone who carries out repairs.

Request a call back How we survey