Case study · north London · semi detached, 1850 to 1918

The damp proof course was there.
Render and concrete went round it.

Damp in the kitchen and at the front of the living room of an empty Victorian house, and a damp cellar below. The house already had a slate damp proof course. The damp was coming from several places, and none of them was the ground rising through it.

See exactly what you get: read a real Vigilant report, published with the client's permission.

Fixed fee from £350Salts tested after the visitNo new damp proof course recommendedReal survey, not a mock up
This is a real Vigilant survey, published with the client's written permission. The client's name, the address and the postcode have been removed, and no photograph shows anything personal or identifies the property. Every reading, temperature, photograph and finding is exactly as recorded on site.

Damp at the bottom of the walls in an old house that already has a damp proof course

We were asked for a focused damp survey of the ground floor and the cellar, inside and outside where needed, to establish the causes of the damp and the class of works needed to put it right.

The property was empty, with access by key safe, so there was no occupier to give a history: when the damp appeared, how the house had been used, or whether there had been leaks.

The house

A Victorian semi detached house of 1850 to 1918, of solid brick, assumed from the age of the house and the exposed brickwork at the front and not established by opening up. The kitchen, the living room and the cellar were inspected inside, with environmental readings at the foot of the staircase, and the front and rear elevations outside at ground floor level. The side elevation could not be inspected outside, because a neighbouring lean to structure is built against it. The upper floors were outside the scope, and no opening up was carried out.

The day was dry, with no rain in the previous 48 hours.

Is it rising damp? The shape of the readings says no

The control in the kitchen, on the partition to the WC, read 8.8 %WME. Two kitchen walls were mapped at four heights.

The partition to the living room, an internal wall with no outside face:

HeightLeftCentreRight
200mm below ceiling9.210.59
1200mm102511.9
600mm413230.3
Skirting, 100mm7.314.39.1

The external side wall:

HeightLeftLeft of centreCentreRight of centreRight
200mm below ceiling7.91011.911.539
1200mm10.4not reached11.51415.1
600mm13.311.2101415
Skirting, 100mm171518.41420

Rising damp is highest at the base and falls away upwards. The partition is drier at its base than at 600mm. The side wall reads 14 to 20 at the skirting, which fits a bridged damp proof course, and then 39 just below the ceiling at its right hand end, roughly where the render has come away outside, which points to rain getting in from above.

In the living room, against a control of 12.3 %WME beside the French door, the high readings were grouped around the front radiator: 49.9 left of it and 24.4 right of it, and 36.6 at 600mm on the return wall next to it, with salts on the wall behind it. The rest of the front return wall is dry at skirting level and above. Left of the front window the wall reads 39.2 at skirting level, and the side wall reads 17 to 18 in patches below 900mm.

The white powder on the kitchen walls

There are soft, fluffy white salt deposits at low level in the kitchen, with peeling paint and blown plaster. A sample of the deposits was tested after the inspection. It did not show the salts associated with rising damp, and was consistent with efflorescence: salts carried to the surface by water evaporating out of the wall.

So the kitchen partition is taking on water from somewhere, and the new decoration is failing where it comes out. Where that water comes from was not established on the day. The partition sits beside the void beneath the living room floor, which appears to take its air from the damp cellar through drilled holes in the cellar wall. That is the first place to look.

What was going round the damp proof course

At the front, a slate damp proof course is visible at the corner of the bay. A painted render plinth to about 600mm runs down past it into the ground. The ground has been built up with concrete against the wall, with gravel over it, and at worst sits only 70mm below the damp proof course, left of the front step, where 150mm is the usual minimum. The air bricks sit at ground level, partly blocked by gravel and mortar.

At the rear, along the rear wall and the rear side wall of the kitchen projection, the render is taken straight down to the level paving and sits in contact with it, so the damp proof course line cannot be seen and rain splashes back off the paving onto the base of the wall.

At the top of the kitchen side wall the render has come away from the brickwork, roughly corresponding to the 39 reading inside, and the lead to the kitchen bay roof has gaps where it meets the render, with debris lying in it.

Also recorded: one blocked gully, one downpipe terminating straight into the ground with no visible route away, a degraded cement fillet and a badly fitted gutter at the front canopy, and loose mortar at the bottom right of the front window.

And the cellar

An old, unconverted coal store with painted brick walls and a solid floor. No wall in it reads dry: the lowest reading, 23.7 %WME, is on the internal wall by the consumer unit. Salts and staining run through the brickwork and a horizontal tide line of staining at low level points to standing water or high ground moisture at some time.

The cellar air was 21.8 °C at 73.6% relative humidity, a dew point of 16.9 °C. The coldest wall was 12.9 °C, 4 degrees below it, so condensation was forming on the cellar walls on the day. There is no ventilation, the door is undercut by about 3mm, and there is light black mould on the ceiling around the old coal chute. On the ground floor, by contrast, every surface was 4.4 degrees or more above the dew point, and the air was no wetter than outside.

What was ruled out, and on what evidence

Supported Bridging or construction defect
At the front the render plinth runs past the slate damp proof course into the ground, and the ground is built up to within 70mm of it. At the rear the render sits on the paving. Both bridge the damp proof course and both throw rain back onto the base of the wall.
Supported Penetrating damp, wind driven rain
The kitchen side wall reads 39 just below the ceiling at its right hand end. Outside, the render has come away at the top of that wall and the lead to the bay roof has gaps.
Supported Salt contamination of plaster
Efflorescence in the kitchen, salts behind the living room radiator and throughout the cellar. The test showed water passing through and drying out of the kitchen walls, not ground salts drawn up from below.
Supported Historic or residual moisture
The kitchen efflorescence and the tide line in the cellar show damp has been present for some time.
Supported Surface condensation
In the cellar only, where the coldest wall was 4 degrees below the dew point.
Cannot exclude Plumbing or drainage leak
No leak was seen and no history was available. But the living room readings are grouped around the front radiator, with dry wall either side, and the pipes come up through the floor beside it.
Cannot exclude Penetrating damp, building defect
The living room side wall reads 17 to 18 in patches, and its outside could not be inspected. The degraded canopy fillet and gutter sit above the cold front corner of the living room.
Excluded Rising damp
A slate damp proof course is present. The readings do not follow the rising damp pattern: the front return wall is dry at skirting level, the kitchen partition is drier at its base than at 600mm, and the elevated low level readings sit where the damp proof course is bridged or beside the radiator.
Excluded Interstitial condensation
Solid ground floor walls, with no cavity or lining in which condensation could form unseen.

The evidence

Photographs from the survey, exactly as taken.

The slate damp proof course at the corner of the bay, close crop.
The slate damp proof course at the corner of the bay, close crop.
At the front, the painted render plinth runs down past the damp proof course into the built up ground and gravel.
At the front, the painted render plinth runs down past the damp proof course into the built up ground and gravel.
Kitchen, the external side wall.
Kitchen, the external side wall.
Kitchen, the partition to the living room: salts and blown plaster.
Kitchen, the partition to the living room: salts and blown plaster.
Kitchen control, on the partition to the WC: 8.8 %WME.
Kitchen control, on the partition to the WC: 8.8 %WME.
Living room, salt signs behind the front wall radiator.
Living room, salt signs behind the front wall radiator.
Living room, the external wall left of the front window: 39.2 %WME at skirting level.
Living room, the external wall left of the front window: 39.2 %WME at skirting level.

So what is causing it?

On the evidence it is highly probable that the damp on the ground floor comes from several outside sources rather than one. At the front, the render plinth bridges the slate damp proof course and the ground has been built up to within 70mm of it. At the rear and along the rear side wall, the render sits on the paving. Rain is getting in at the top of the kitchen side wall where the render has come away. A leak from the pipework to the front living room radiator cannot be excluded and needs testing.

It is not rising damp, and a new damp proof course is not the answer: one is already there, and it cannot work while it is bridged.

The kitchen partition is taking on moisture from a source not established on the day, and the void beneath the living room floor is the first place to look. The cellar is an unconverted cellar below ground and will always take some moisture through its walls. With no ventilation, condensation forms on its cold walls.

What to do about it, and in what order

First, pressure test the heating and check the pipework to the front living room radiator where it comes up through the floor, before any drilled samples, so that a leak is not mistaken for anything else.

Then stop the water outside. Install air drains along the front, the rear and the rear side wall of the kitchen, so the ground sits at least 150mm below the damp proof course and rain stops splashing back. The air drain is the preferred option, with cutting the render back above the damp proof course with a bellcast drip as the alternative or addition. Clear the front air bricks and fit periscope vents where they sit at or below ground level.

Repair and refix the render at the top of the kitchen side wall, renew the lead flashing to the kitchen bay roof, confirm where the rear downpipe discharges and clear the blocked gully.

Then the lesser items: a lead flashing in place of the cement fillet at the front canopy, the canopy gutter refitted, and the loose mortar at the front window repointed.

Ventilate the cellar with air bricks or a vented cover at the old coal chute and a gap of around 10mm under its door, and clean the mould off its ceiling. Using the cellar as a room would need a waterproofing design by a specialist, which is a project in its own right.

Only once the sources are stopped and the walls have dried, brush the salt deposits off dry, make good the blown plaster in the kitchen and behind the front radiator, and redecorate with a breathable paint. Because the deposits are efflorescence, full replastering is not needed as a matter of course: replaster with a system suited to salt contaminated masonry only where drilled samples show the plaster is still holding moisture.

And what should not be done

Do not have a new damp proof course put in. Do not redecorate before the sources are stopped, because the damage will return.

How confident, and what would settle it

The report records this as highly probable on the evidence, not confirmed, and names what would settle it: a pressure test of the heating first, then drilled samples with a salts test at the kitchen partition at 600mm, the base of the kitchen side wall and the living room wall beside the front radiator, measured against the controls of 8.8 and 12.3 %WME. Lifting a floorboard near the front wall would show the space beneath the living room floor. A drainage check of the rear downpipe, an inspection of the side wall with the neighbour's permission, and a return visit to the cellar after heavy rain would close the rest.

Been told you need a damp proof course?

Fixed fee from £350. We carry out no remedial work, sell no products, and take no commission or referral fee from anyone who carries out repairs.

Request a call back How we survey